Automatic Sampling Gas Chromatography Equipment with Fid Detector

Automatic Sampling Gas Chromatography Equipment with Fid Detector

Model NO.: GC5890N
Trademark: Haida
Transport Package: Strong Wooden Case
Origin: Guangdong, China
Automatic Sampling Gas Chromatography Equipment With FID Detector

Description:
This advanced gas chromatograph is designed for automatic sampling and features a Flame Ionization Detector (FID). It supports multiple detectors and capillary columns with shunt/unshunt injection systems. Fully compatible with Agilent 6890N instruments, it ensures seamless integration with detectors, control boards, and chromatographic workstations. Known for its excellent performance, stability, and reliability, this equipment delivers precise temperature control up to 0.01°C.

Applications:
Petroleum, chemical industry, food, pharmaceuticals, environmental protection, disease control, safety supervision, water, electricity, metallurgy, scientific research institutes, and quality inspection departments.

Supporting Products:
Headspace injectors, gas generators, gas purifiers, thermal analyzers, pyrolyzers, etc.

Performance Highlights:
1. New integrated digital electronics for high precision and stable operation. Temperature control accuracy reaches 0.01°C.
2. Includes boot self-diagnosis, stopwatch, timer, power storage protection, key lock, anti-power fluctuation, network communication, and remote control functions.
3. Unique sample system design lowers detection limits for enhanced sensitivity.
4. Supports automatic/manual gas six-way injection valves, headspace injectors, thermal samplers, pyrolysis furnaces, methane converters, and more.
5. Faster temperature stabilization in the furnace for efficient analysis.
6. Compatible with FID, TCD, FPD, NFD, PDHID detectors. Each can be independently controlled. FID is easy to disassemble for cleaning or nozzle replacement. TCD stabilizes within 20 minutes.
7. Features automatic online detection capabilities for real-time monitoring.

Parameters:
(The table parameters are based on the company's standard model; customizations are available upon request)
Column Temperature Box
Furnace size 28×30×18cm
Temperature range Room temperature 5~450ºC
Temperature setting 1 ºC; Program Set heating rate 0.1 ºC
Maximum heating rate 120ºC/ min
Temperature stability When ambient temperature changes 1 ºC, it is 0.01 ºC
Program warming up 7 degree Program warming up
Operation Column loss compensation (dual channel)
Incoming Sample Port
A variety of feed-like port can be matched: filling column inlet, shunt/not shunt capillary inlet, the program temperature Leng head into the sample mouth.
Hydrogen Flame ionization detector (FID)
Maximum operating temperature 400ºC
Detection limit ≤5×10-12g/s [n-C16]
Baseline Drift ≤5×10-13A/30min
Noise ≤2×10-13A 
Dynamic linear Range ≥107
Thermal conductivity Pool Detector (TCD)
Maximum operating temperature 400ºC
Sensitivity ≥10000mv.ml/mg [n-C16]
Baseline Drift ≤100μV/30min
Noise ≤2×10-13A
Dynamic linear Range ≥104
Flame Photometric detectors (FPD)
Maximum operating temperature 250ºC
Detection limit ≤2x10-13 gs(P),≤5x10-11g/s(S)
Dynamic linear Range ≥103(P),≥102(S)
Noise ≤2×10-12A 
Baseline Drift ≤4x10-11A/30min
Electronic capture Detector (ECD)
Maximum operating temperature 350ºC
Detection limit ≤1x10-14g/ml(y-666)
Dynamic linear Range ≥104
Noise ≤20μA 
Baseline Drift ≤50μV/30min
Nitrogen and phosphorus detectors (NPD)
Maximum operating temperature 400ºC
Detection limit ≤5x10-13 gs(P),≤1x10-12g/s(N)
Aluminum-based Intermediate Alloys